Merchant Shipping (Load Line) First Amendment Rules, 1982

                         

MINISTRY OF SHIPPING AND TRANSPORT
(Shipping Wing) 

NOTIFICATION 

New Delhi, the 6th July, 1982 

(Merchant Shipping) 

            G.S.R. 486(E)-Whereas a draft to amend the Merchant Shipping (Load Line) Rules, 1979 was published, as required by Section 344 of the Merchant Shipping Act, 1958 (44 of 1958) at pages 402-412 of the Gazette of India, Part II, Section 3(i) dated 6.2.82 with the Notification of the Government of India in the Ministry of Shipping and Transport (Shipping Wing) G.S.R. No.132 inviting objections and suggestions from all persons likely to be affected thereby till the expiry of sixty days from the date of publication of the said notification in the official gazette.           

            And whereas the copies of the said gazette were made available to the public on 4.3.1982; 

            And whereas no objections or suggestions have been received from the public on the said draft; 

            Now, therefore, in exercise of the powers conferred by Section 311 read with Section 436 of the said Act, the Central Government hereby makes the following rules, namely :- 

RULES 

            1.         short title and commencement ---(1) These rules may be called the Merchant Shipping (Load Line) First Amendment Rules, 1982. 

            (2)        They shall come into force on the date of their publication in the Official Gazette. 

            2.         In the Merchant Shipping (Load Line) Rules, 1979 for the Fourth Schedule the following Schedule shall be substituted, namely 

"FOURTH SCHEDULE" 

(see rules 5 and 26) 

Form L.L. 4D (Revised)

 

 

Issued by the Government  

Government of India

 INTERNATIONAL CONVENTION ON LOAD LINES, 1966 

RECORD OF CONDITIONS OF ASSIGNMENT LOAD LINE SURVEY

 

_____________________________________________________________________________________

 

Name of Ship     .           .           .           .           .           .           .           .           . 

Port of Registry  .           .           .           .           .           .           .           .           . 

Nationality                     .           .           .           .           .           .           .           .            

Distinctive Number or Letters      .           .           .           .           .           .           .          

Shipbuilders      .           .           .           .           .           .                       .           .         

Yard Number     .           .           .           .           .           .           .           .           . 

Date of Build/Conversion .           .           .           .           .           .           . 

Freeboard assigned as a ship of Type      .           .           .           .           .            

Classification     .           .           .           .           .           .           .           .           . 

Date and place of initial survey    .           .           .           .           .           .            

____________________________________________________________________________________

 
 
DOORWAYS IN SUPERSTRUCTURES, EXPOSED MACHINERY CASINGS AND DECKHOUSES PROTECTING OPEINING IN FREEBOARD AND SUPERSTRUCTURE DECKES.
Location     Ref.No.
on Sketch
or Plan
Number and
size of
openings
Height of Sills Closing Appliances
Type and
Material
Number of
Clips

_________________________________________________________________________________________________
 In forecastle bulkhead
_________________________________________________________________________________________________
In bridge forward bulkhead
_________________________________________________________________________________________________
In bridge after bulkhead
_________________________________________________________________________________________________
In raise quarter deck bulkhead
_________________________________________________________________________________________________
In poop bulkhead
_________________________________________________________________________________________________
In exposed machinery casings
on free board or raised quarter decks
_________________________________________________________________________________________________
In exposed machinery casings on
superstructures decks
_________________________________________________________________________________________________
In machinery casings within
superstructures or
deckhouses on freeboard deck
_________________________________________________________________________________________________
In deckhouses in Position 1
enclosing openings leading
below freeboard deck.
_________________________________________________________________________________________________
In deckhouses in Position 2
enclosing openings leading
within enclosed superstructures
or below freeboard deck
___________________________________________________________________________________________
In exposed pump room casings.
____________________________________________________________________________________________

 HATCHWAYS AT POSITIONS 1 AND 2 CLOSED BY PORTABLE COVERS SECURED WEATHERTIGHT BY TARPAULINS AND BATTENING DEVICES.
__________________________________________________________________________________________

Position and Reference No. on Sketch or Plan
___________________________________________________________________________________________
Dimensions of clear opening at top of coaming
___________________________________________________________________________________________
Height of coaming above deck
___________________________________________________________________________________________

PORTABLE BEAMS                  Number _______________________________

                        Spacing _______________________________ 

                        b1 x ff      ____________________________________

                                    D x tf       ________________________________

 

                                    Boaring surface ___________________________

Means of securing each beam                 _________________________________

 

___________________________________________________________________________________________

            {           Material ______________________________________

                                    {

                                    {           Thickness______________________________________

PORTABLE                   {

COVERS                      {

                                    {           Direction

{           fitted       _______________________________________

                                    {          

                                    {           Boaring

{           surface  _______________________________________ 
 

___________________________________________________________________________________________

Spacing of Cleats                      

___________________________________________________________________________________________

TARPAULINS                {           No.of layers       _______________________________________

                                    {           Material             _______________________________________           

___________________________________________________________________________________________

Means of securing each section of covers :
Are wood covers fitted with galvanized end bands ?

HATCHWAYS AT POSITIONS 1 AND 2 CLOSED BY WEATHERTIGHT COVERS OF STEEL (OR OTHER EQUIVALENT MATERIAL) FITTED WITH GASKETS AND CLAMPING DEVICES. 
___________________________________________________________________________________________

Position and Reference No. on  Sketch or Plan
___________________________________________________________________________________________

Dimensions of clear opening at top of coaming
___________________________________________________________________________________________

Height of coamings above deck
___________________________________________________________________________________________

Type of cover or Patent Name
                                                                                                                                                                                    Material __________________________________
 

___________________________________________________________________________________________

MACHINERY SPACE OPENING AND MISCELLANEOUS OPENINGS IN FREEBOARD AND SUPERSTRUCTURE DECKS
___________________________________________________________________________________________

Position and Reference No.  on Sketch or Plan
___________________________________________________________________________________________

                                    {           Material             ________________________________

COVER                         {          

            {           How attached    ________________________________

 

Number and Spacing of Toggles

___________________________________________________________________________________________

 

 

___________________________________________________________________________________________

Position and Reference No. on Sketch or Plan

___________________________________________________________________________________________

Dimensions
Height of coaming

 

___________________________________________________________________________________________

                                    {           Material             ________________________________

COVER                        {          

            {           How attached    ________________________________

 

Number and Spacing of Toggles

___________________________________________________________________________________________

VENTILATORS ON FREEBOARD AND SUPERSTRUCTURE DECKS

(POSITION 1 AND 2) 

___________________________________________________________________________________________

Deck on which fitted Number fitted Coaming Type (State Patent Name if any) Closing Appliances
Dimensions Height

___________________________________________________________________________________________


___________________________________________________________________________________________

AIR PIPES ON FREEBOARD AND SUPERSTRUCTURE 

______________________________________________________________________________________________

Deck on which fitted Number fitted Coaming Type (State Patent Name if any) Closing Appliances
Dimensions Height
_________________________________________________________________________________________



___________________________________________________________________________________________

 CARGO PORT AND OTHER SIMILAR OPENINGS

 

__________________________________________________________________________________________

Position of Port  Dimensions of    Distance of lower edge          Securing devices           Remarks
                        Opening.            from freeboard deck     

________________________________________________________________________________________

 

 ________________ ________________________________________________________________________

 SCUPPERS, INLETS AND DISCHARGES 

__________________________________________________________________________________________

 

State if Scupper
or Discharge
Number

Pipe

From Vertical distance above top of keel Number, Type & Material of Discharge Valves Position
 of
 Controls
Diameter Thickness Material Discharge Uppermost Valve
Outlet in hull Inboard end
__________________________________________________________________________________________

__________________________________________________________________________________________

 

S—Scupper                   MS—Mild Steel                  SD-Screw down
D—Discharge                CS—Cast Steel                  ANR—Automatic non-return
                                    GM—Gum metal                SD ANR—Screw down automatic non-return

            Any other approved material to be designated. 

NOTE : Symbols may be used at the discretion of the Administration. 

__________________________________________________________________________________________

SIDE SCUTTLES

__________________________________________________________________________________________

Position Number fitted Clear glass size Fixed or opening

Material

Type of Class & thickness Standard used and type No.
Frame Deadlight

____________________________________________________________________________________________

 

____________________________________________________________________________________________

Indicate the vertical distance between the freeboard deck and the lower sill of the side scuttle positioned at the greatest vertical distance below the freeboard deck.
____________________________________________________________________________________________

FREEING PORTS
  Length of Bulwark Height of Bulwark Number and Size of Freeing Ports each side Total Area each side Required Area each side
____________________________________________________________________________________________
Freeboard Deck After Well_______________________________________________________________________
_____________________________________________________________________________________________

Superstructure Deck_____________________________________________________________________________
_____________________________________________________________________________________________

State fore and aft position of each freeing port in relation to super-                   After Well
structure end bulkheads                                                                              Forward Well  

Particulars of shutters, bars or rails fitted to freeing ports

 Height of  lower edge of freeing port above deck.

PROTECTION OF THE CREW

 

State particulars of bulwarks or guardrails on freeboard and Superstructure decks :
State Details of life lines, walkways, gangways or
underdeck passengerways where required to be fitted :

___________________________________________________________________________________________

 TIMBER DECK CARGO FITTINGS

 

State particulars of uprights, sockets, lachings, guardrails and lifelines:
____________________________________________________________________________________________

 OTHER SPECIAL FEATURES

___________________________________________________________________________________________

            The conditions of assignment shown on this form are a record of the arrangements and fittings provided on the ship and are in accordance with the requirements of the relevant regulations of the International Convention on Load Lines, 1966, and the Merchant Shipping (Load Line) Rules, 1979. 

 ………………………..

(Surveyor's signature)

 

………………………….
(Date)

 

_____________________________________________________________________________________________________

 

{ No. SW/5-MSR(10)/81-MA}

S.N. KAKAR,Director

Go Top

Go Back